Products / Liquid Cooling / ROCAS 215 Hybrid
Representative product render. Final appearance may vary.
Liquid Cooling / C&I
ROCAS 215 Hybrid
215 kWh | Hybrid PV + BESS
Combined PV, battery and grid operation with integrated EMS. The PDF lists black-start support, independent PV inputs and grid/backup interfaces. Four-level fire protection is described on the web page.
215 kWh100 kW
PRODUCT DATA
Technical specifications
BATTERY
| Cell chemistry / rating | LFP; 3.2 V / 280 Ah |
|---|---|
| Configuration | 1P240S |
| System energy | 215.04 kWh |
| DC range / nominal | 648-864 V / 768 V |
| Cycle life | 8,000 cycles (0.5P, 25 ±2°C, 70% SOH) |
PV INPUT
| Maximum power / voltage | 156 kW / 1,100 V |
|---|---|
| MPPT range / rated | 180-850 V / 550 V |
| Start voltage | 195 V |
| Input / short-circuit current | 2 ×32 A / 2 ×40 A |
| MPPT quantity | 10 |
AC / GRID AND BACKUP
| Rated power / max. current | 100 kW / 166.7 A |
|---|---|
| Voltage / wiring | 400 V (-15% to +15%); 3P+N+PE |
| Grid frequency | 50/60 Hz; 45-55 / 55-65 Hz |
| Off-grid switching | <20 ms (PDF) |
SYSTEM / ENVIRONMENT
| Dimensions W × D × H | 1,550 ×1,300 ×2,300 mm |
|---|---|
| Included equipment | Hybrid inverter and air conditioning |
| Weight / efficiency | 2,500 kg / ≥88% |
| Ambient / humidity | -20 to +55°C / ≤95% |
| Cooling / fire suppression | Liquid cooling / aerosol |
| Communications | Ethernet / CAN / RS485 |
| Maximum altitude | 2,000 m |
| Listed standards* | GB/T 34120; GB/T 36276; UN 38.3 |
Technical notes & source documentation
PDF specifications used. Web gives MPPT 180-800 V, efficiency >88% and string count 6/6. MPPT/current allocation requires confirmation.
Reference model: SE215L-100KGC (PDF); SE215A-100K (web). Listed standards are source references; model-specific conformity documentation is available for project review.
Manufacturer source page ↗Complete Liquid Cooling portfolio ↓